1.SC Codes
287
harness being exposed)
2. Replace the controller board.
SC730-10 to 13
Error Name
ï‚· 730-10: Stacker 1: Entrance Motor Error
ï‚· 730-11: Stacker 1: Proof Tray Exit Motor Error
ï‚· 730-12: Stacker 1: Transport Motor Error
ï‚· 730-13: Stacker 1: Shift Exit Motor Error
Pattern
ï‚· 730-10: D
ï‚· 730-11: D
ï‚· 730-12: D
ï‚· 730-13: B
Error Condition
Motor driver detected an error. (This SC is issued when the error was detected for the first time).
Major Cause
ï‚· Power of downstream unit is not turned on.
ï‚· Motor is defective.
ï‚· Overcurrent to the motor
ï‚· Motor driver overheat detected
Corresponding components:
ï‚· 730-10: Stacker 1: Entrance Motor (M1)
ï‚· 730-11: Stacker 1: Proof Tray Exit Motor (M6)
ï‚· 730-12: Stacker 1: Transport Motor (M3)
ï‚· 730-13: Stacker 1: Shift Exit Motor (M4)
Solution
1. Turn the power off and on to check the SC occurs again.
2. Check the motor connections.
3. Replace the motors.
4. Replace the controller board.
SC730-20, 21, 30 to 35
Error Name
ï‚· 730-20: Stacker 1: Proof Tray JG Motor Error