1.SC Codes
316
SC750
SC750-01
Error Name
Perfect Binder: Downstream Device Communication Error
Pattern
D
Error Condition
ï‚· Break continued for 10 seconds or longer.
ï‚· Anther STN was received during frame receipt.
ï‚· No response even after resending 3 times.
Major Cause
ï‚· Power of downstream unit is not turned on.
ï‚· Relay board is defective/ connector loose, damaged, or defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the relay board.
ï‚· Replace the harness.
SC750-10
Error Name
Perfect Binder: Master-to-Slave Communication Error 1
Pattern
D
Error Condition
Communication alarm issued when master control board could not communicate with the slave control
board for over 5 sec.
Major Cause
ï‚· Master control board is defective.
ï‚· Slave Control Board is defective.
ï‚· Connector loose, damaged, or defective.