1.SC Codes
360
SC751
SC751-10
Error Name
Glue Heater Startup Error 3
Pattern
D
Error Condition
The warm-up temperature was below the +-5C target for the glue vat temperature. (Not detected within
100 sec. after machine warm-up.)
Major Cause
ï‚· Internal temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
SC751-11
Error Name
Perfect Binder: Glue Heater Startup Error 4
Pattern
D
Error Condition
At the end of temperature adjustment at power on, warm-up did not complete within 500 sec.
The glue vat temperature did not reach the warm-up temperature within 500 sec.
Major Cause
ï‚· Glue heater connector loose, damaged, or defective
ï‚· Heater defective
ï‚· Slave board defective