1.SC Codes
361
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
SC751-12
Error Name
Perfect Binder: Ambient Temperature Error
Pattern
D
Error Condition
Ambient temperature is between 0°C and -20°C (not within the operational range)
Major Cause
ï‚· Internal temperature thermistor connector loose, damaged, or defective
ï‚· Thermistor defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
 Check the room temperature (0°C or higher).
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
SC751-13
Error Name
Perfect Binder: Glue Low Limit Late Error
Pattern
D
Error Condition
The level of the glue in the vat was detected below the lower limit for four times.
Major Cause
ï‚· Glue clogged, or glue supply defective
ï‚· Glue level thermistor connector loose, damaged, or defective