1.SC Codes
370
Pattern
D
Error Condition
The cover horizontal registration sensor (S) A/D input value was higher than 3.2 to 3.54V, and the A/D
input value did enter the range 3.2 to 3.54V, even though the sensor D/A output value output was
lowered 0.04V.
Major Cause
ï‚· Cover horizontal registration sensor (S) connector loose, damaged, or defective
ï‚· Sensor defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the cover horizontal registration sensor (S).
ï‚· Replace the slave control board.
ï‚· Replace the sensor harness.
SC751-28
Error Name
Perfect Binder: Cover Horizontal Registration Sensor (L) Adjustment Low Value Error
Pattern
D
Error Condition
The cover horizontal registration sensor (L) A/D input value was higher than 3.2 to 3.54V, and the A/D
input value did enter the range 3.2 to 3.54V, even the sensor D/A output value output was lowered
0.04V.
Major Cause
ï‚· Cover horizontal registration sensor (L) connector loose, damaged, or defective
ï‚· Sensor defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the cover horizontal registration sensor (L).
ï‚· Replace the slave control board.