1.SC Codes
394
Pattern
D
Error Condition
At the start of spine fold operation, the spine plate close sensor did not go OFF, even after the spine
plate motor operated for 505 ms.
Major Cause
ï‚· Spine plate motor connector loose, damaged, or defective
ï‚· Motor defective
ï‚· Spine close sensor connector loose, damaged, or defective
ï‚· Sensor defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the spine plate motor.
ï‚· Replace the spine close sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
SC751-67
Error Name
Perfect Binder: Front Door Lock Error
Pattern
D
Error Condition
The front door lock release sensor did not go off, even though the door was locked.
Major Cause
ï‚· Front door lock solenoid defective
ï‚· Front door lock release sensor defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the front door lock solenoid.
ï‚· Replace the front door lock release sensor.
ï‚· Replace the master control board.