1.SC Codes
435
Error Condition
When rotating signature to main grip binding position, the MG rotate-to-binding position sensor did not
go ON, even though the MG rotate motor had operated for 2250 ms.
Major Cause
ï‚· MG rotate motor defective
ï‚· MG rotate-to-binding position sensor defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the MG rotate motor.
ï‚· Replace the MG rotate-to-binding position sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
SC752-54
Error Name
Main Grip Rotate-to-Binding Position Lag Error
Pattern
D
Error Condition
When rotating signature to main grip turnover position, MG rotate-to-binding position sensor did not go
OFF, even though the MG rotate motor had operated for 500 ms.
Major Cause
ï‚· MG rotate motor defective
ï‚· MG rotate-to-binding position sensor defective
ï‚· Connector harness loose, damaged, or defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the MG rotate motor.
ï‚· Replace the MG rotate-to-binding position sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.