1.SC Codes
441
Solution
ï‚· Reconnect the connector.
ï‚· Replace the main grip motor (F).
ï‚· Replace the MG open sensor (F).
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
SC752-64
Error Name
Perfect Binder: Main Grip Close Sensor (F) Late Error
Pattern
D
Error Condition
At the start of the main grip open operation, the MG close sensor (F) did not go ON, even after the MG
motor (F) had operated for 3000 ms.
Major Cause
ï‚· MG motor (F) defective
ï‚· MG close sensor (F) defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the MG motor (F).
ï‚· Replace the MG close sensor (F).
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
SC752-65
Error Name
Perfect Binder: Main Grip Close Sensor (F) Lag Error
Pattern