EasyManua.ls Logo

Ricoh Pro 8300S - Sc753-59; Sc753-60

Ricoh Pro 8300S
963 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.SC Codes
488
SC753-59
Error Name
Perfect Binder: Glue level thermistor adjustment value error
Pattern
B
Error Condition
 Temperature detected by glue level thermistor out of range, 128°C+-14°C for low limit.
 Temperature detected by glue level thermistor out of range, 142°C+-10°C for high limit.
ï‚· The glue level thermistor adjustment value for low limit is larger than the high level.
 Glue level thermistor target value is 5°C off the values of the low and high limit.
Major Cause
ï‚· Master control board EEPROM data error
ï‚· Glue level thermistor connector loose, broken, defective
ï‚· Thermistor defective
ï‚· Slave board disconnected, defective
Solution
ï‚· Reconnect the connector.
ï‚· Re-set the value for glue level thermistor.
ï‚· Replace the gluing unit.
ï‚· Replace the master control board EEPROM.
ï‚· Replace the slave board.
ï‚· Replace the master control board.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-60
Error Name
Perfect Binder: Timing sensor adjustment high value error
Pattern
B
Error Condition
The timing sensor A/D input value was lower than 3.0 to 3.5V, the A/D input value did not go higher than
3.0 to 3.5V, even after timing sensor D/A output value was higher than 3.5V.

Table of Contents

Other manuals for Ricoh Pro 8300S

Related product manuals