1.SC Codes
510
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-13
Error Name
Perfect Binder: Glue Roller HP Sensor Lag Error
Pattern
B
Error Condition
During glue supply, the glue roller HP sensor did not go OFF, even though the glue roller motor was
operating for 2400 ms.
Major Cause
ï‚· Glue pellets jammed
ï‚· Glue supply motor defective
ï‚· Glue roller HP sensor defective
ï‚· Connector loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the glue supply motor.
ï‚· Replace the glue roller HP sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-14
Error Name
Perfect Binder: Front Door Lock Error
Pattern
B
Error Condition
Front door lock release sensor did not go off, even though the door was locked.