1.SC Codes
529
Solution
ï‚· Reconnect the connector.
ï‚· Replace the stacking tray lift motor.
ï‚· Replace the stack tray HP sensor.
ï‚· Replace the master control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-42
Error Name
Perfect Binder: Stack Tray HP Sensor Lag Error
Pattern
B
Error Condition
When the tray moved from the home position, the HP sensor did not go OFF after enough time for 10
mm of movement had elapsed.
Major Cause
ï‚· Stack tray HP sensor defective
ï‚· Stacking tray motor defective
ï‚· Harness connector loose, damaged, or defective
ï‚· Master control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the stacking tray motor.
ï‚· Replace the stack tray HP sensor.
ï‚· Replace the master control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-43
Error Name
Perfect Binder: Stack Weight Move HP Sensor Late Error