1.SC Codes
541
ï‚· Signature out of position, snagged on main grip
ï‚· Connector harness loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the MG lift motor.
ï‚· Replace the signature exit sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
ï‚· Clear the signature jam.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-60
Error Name
Perfect Binder: Main Grip HP Sensor (L) Late Error
Pattern
B
Error Condition
During main grip lift, the MG HP sensor (L) did not go ON, even though the main grip lift motor had
operated for 6185 ms.
Major Cause
ï‚· MG lift motor defective
ï‚· MG HP sensor (L) defective
ï‚· Connector harness loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the MG lift motor.
ï‚· Replace the MG HP sensor (L).
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.