1.SC Codes
559
Major Cause
ï‚· Power of downstream unit not turned on
ï‚· Motor defective (Blade motor)
ï‚· Connector disconnected
ï‚· Overload
ï‚· Home position sensor defective (Blade HP sensor)
Solution
1. Turn the power OFF and ON.
2. Check the connector.
Check the connection between the blade motor/blade HP sensor and main board. (Check all the
connectors are properly connected.)
If the connector is not connected properly, reconnect the connector. Turn the power OFF/ON, and
then check if the SC recurs.
3. Check the harness.
Check if the harness between the blade motor/blade HP sensor and main board is damaged or
exposed. If so, replace the harness. Turn the power OFF/ON, and then check if the SC recurs.
4. Replace the components.
ï‚· If the blade motor does not operate, replace the motor.
ï‚· If the blade HP sensor does not detect, replace the sensor.
ï‚· If the main board on the ring binder is defective, replace the board.
SC756-20
Error Name
Ring Binder: Pre-Punch Side Fence HP Error
Pattern
B
Error Condition
ï‚· The jogger fences in the pre-punch jogger unit moved from home position, but home position is
detected even after a specified time had passed. (The first time is reported as a jam. An SC is
issued the second time this occurs.)
ï‚· The jogger fences in the pre-punch jogger unit moved to the home position, but home position is
not be detected within a specified time. (The first time is reported as a jam. An SC is issued the
second time this occurs.)
* The first time: Pre-punch jam (J334)