1.SC Codes
568
3. Check the harness.
Check if the harness between the spine clamp motor/clamp HP Sensor and the sub board is
damaged or exposed. If so, replace the harness. Turn the power OFF/ON, and then check if the
SC recurs.
4. Replace the components.
ï‚· Replace the spine camp motor.
ï‚· Replace the clamp HP sensor.
ï‚· Replace the sub board.
SC756-40
Error Name
Ring Binder: Binder Unit Run-Out Error
Pattern
B
Error Condition
ï‚· The run-out roller moved from home position, but home position is detected even after a specified
time had passed. (The first time is reported as a jam. An SC is issued the second time this occurs.)
ï‚· The run-out roller has moved to the home position, but home position is not be detected within a
specified time. (The first time is reported as a jam. An SC is issued the second time this occurs.)
*First time jam: Pre-punch jogger jam (J343)
Major Cause
ï‚· Power of downstream unit not turned on
ï‚· Runout press roller motor defective
ï‚· Connector disconnected
ï‚· Overload
ï‚· Runout roller HP sensor defective
Solution
1. Turn the power OFF and ON.
2. Check the connector.
Check the connection between the runout press roller motor / runout roller HP sensor and the sub
board. (Check all the connectors are completely connected.)
If the connector is not connected properly, reconnect the connector. Turn the power OFF/ON, and
then check if the SC recurs.
3. Check the harness.
Check if the harness between the runout press roller motor / runout roller HP sensor and the sub
board is damaged or exposed. If so, replace the harness. Turn the power OFF/ON, and then check