1.SC Codes
573
Error Condition
At initialization or ring binding, the timing sensor does not turn ON or OFF within the prescribed time.
(The first time is reported as a jam. An SC is issued the second time this occurs.)
*First time jam: Punch motor jam (J345)
Major Cause
ï‚· Power of downstream unit not turned on
ï‚· Clamp unit motor defective
ï‚· Connector disconnected
ï‚· Overload
ï‚· Bind timing sensor defective
Solution
1. Turn the power OFF and ON.
2. Check the connector.
Check the connection between the clamp unit motor/bind timing sensor and the sub board. (Check
all the connectors are completely connected.)
If the connector is disconnected, reconnect the connector. Turn the power OFF/ON, and then
check if the SC recurs.
3. Check the harness.
Check if the harness between the clamp unit motor/bind timing sensor and the sub board is
damaged or exposed. If so, replace the harness. Turn the power OFF/ON, and then check if the
SC recurs.
4. Replace the components.
ï‚· Replace the clamp unit motor.
ï‚· Replace the bind timing sensor.
ï‚· Replace the sub board.
SC756-46
Error Name
Ring Binder: Clamp Unit HP Error
Pattern
B
Error Condition
ï‚· At initialization or during ring binding, the unit did not arrive at home position within the prescribed
time. (The first time is reported as a jam. An SC is issued the second time this occurs.)
ï‚· The clamp unit moved from home position, but home position is detected even after the prescribed