1.SC Codes
625
Major Cause
ï‚· BiCU replacement mistake
ï‚· BiCU is defective.
Solution
1. Re-input the machine serial number into SP5-811-004.
2. Replace the BiCU.
SC995-02
Error Name
CPM Setting Error
Pattern
D
Error Condition
Machine serial number (11 digits) is incorrect.
Major Cause
ï‚· NVRAM replacement mistake
ï‚· NVRAM is defective.
Solution
1. Re-input the machine serial number into SP5-811-004.
Download data using SP5-825-001.
2. Replace the NVRAM.
SC995-03
Error Name
CPM Setting Error
Pattern
D
Error Condition
Machine serial number (11 digits) is incorrect.
Major Cause
ï‚· Controller board replacement mistake
ï‚· Controller board is defective.