5.Other Information
871
[C]. Do not tighten the screw at [C] ( x1).
4. While looking at the scale, pull the registration adjustment plate approximately 3 mm to the front.
5. Remove the screw that you moved in Step 3, and then fasten at its original position ( x1).
6. Re-attach the right tandem tray ( x2).
7. To compensate for the 3 mm shift to the front:
ï‚· Disable the registration adjustment in main scan direction in either Adjustment Settings for
Operators 1-105-01 to 08, or do SP1-917-001 to 008 [Side-to-Side Reg Disable] and change
"0" to "1".
ï‚· Adjust the registration in SP1-002-001 (Main Scan Regist (Shift: Off): Tray 1).
False Drum Lubricant Near-end Alert
A jammed feeler can cause the machine to issue a false drum lubricant near-end alert.
Cause
The feeler that detects lubricant near-end is stuck and caused the system to constantly issue a false