1.SC Codes
574
time. (The first time is reported as a jam. An SC is issued the second time this occurs.)
*First time jam: Punch motor jam (J345)
Major Cause
ï‚· Power of downstream unit not turned on
ï‚· Clamp unit motor defective
ï‚· Connector disconnected
ï‚· Overload
ï‚· Clamp unit HP sensor defective
Solution
1. Turn the power OFF and ON.
2. Check the connector.
Check the connection between the clamp unit motor/clamp unit HP sensor/bind timing sensor and
the sub board. (Check all the connectors are completely connected.)
If the connector is disconnected, reconnect the connector. Turn the power OFF/ON, and then
check if the SC recurs.
3. Check the harness.
Check if the harness between the motor/sensors and the sub board is damaged or exposed. If so,
replace the harness. Turn the power OFF/ON, and then check if the SC recurs.
4. Replace the components.
ï‚· Replace the clamp unit motor.
ï‚· Replace the clamp unit HP sensor.
ï‚· Replace the bind timing sensor.
ï‚· Replace the sub board.
SC756-47
Error Name
Ring Binder: Spine Alignment Error
Pattern
B
Error Condition
During alignment, timeout occurred when the alignment pin is moving to the top or to the home position.
This timeout recurs at the second attempt.
Major Cause
ï‚· Power of downstream unit not turned on
ï‚· Alignment pin motor defective