1.SC Codes
598
ï‚· 816-79: Subsystem Error
ï‚· 816-80: Subsystem Error
ï‚· 816-81: Subsystem Error
ï‚· 816-82: Subsystem Error
ï‚· 816-83: Subsystem Error
ï‚· 816-84: Subsystem Error
ï‚· 816-85: Subsystem Error
ï‚· 816-86: Subsystem Error
ï‚· 816-87: Subsystem Error
ï‚· 816-88: Subsystem Error
ï‚· 816-89: Subsystem Error
ï‚· 816-90: Subsystem Error
ï‚· 816-91: Subsystem Error
ï‚· 816-92: Subsystem Error
ï‚· 816-93: Subsystem Error
ï‚· 816-94: Subsystem Error
ï‚· 816-95: Subsystem Error
ï‚· 816-96: Subsystem Error
ï‚· 816-98: Subsystem Error
Pattern
ï‚· 816-01 to 69, 816-71 to 98: D
ï‚· 816-70: C
Error Condition
Energy saving I/O subsystem detected abnormality.
Major Cause
ï‚· Energy saving I/O subsystem is defective.
ï‚· Energy saving I/O subsystem detected a controller board error (non response).
ï‚· Error was detected during preparation for transition to STR.
ï‚· SC816-99 occurred as a subsystem error except for any error from -06 to 96.
Solution
Turn the main power OFF and then ON. See if the SC recurs. If so, take the following steps. After each
step, turn the main power OFF/ON, and see if the SC recurs.
1. Update the "System/Copy" firmware and the other system firmware modules.
2. Disable the STR shift function using SP5-191-001 (Power Str Set).
3. Replace the controller board.