1.SC Codes
359
Major Cause
ï‚· Internal temperature thermistor defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
SC750-89
Error Name
Perfect Binder: Glue Heater Startup Error 2
Pattern
D
Error Condition
The warm-up temperature was above the +-5C target for the glue vat temperature. (Not detected within
100 sec. after machine warm-up.)
Major Cause
ï‚· Internal temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.