EasyManua.ls Logo

Ricoh Pro 8320 - Sc753-53

Ricoh Pro 8320
963 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.SC Codes
484
Major Cause
ï‚· Internal temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-53
Error Name
Perfect Binder: Glue heater startup error 3
Pattern
B
Error Condition
The warm-up temperature was below the +-5C target for the glue vat temperature. (Not detected within
100 sec. after machine warm-up.)
Major Cause
ï‚· Internal temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the internal temperature thermistor.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
ï‚· Replace the thermistor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.

Table of Contents

Other manuals for Ricoh Pro 8320

Related product manuals