1.SC Codes
485
SC753-54
Error Name
Perfect Binder: Glue heater startup error 4
Pattern
B
Error Condition
At the end of temperature adjustment at power on, warm-up did not complete within 500 sec. The glue
vat temperature did not reach the warm-up temperature within 500 sec.
Major Cause
ï‚· Glue heater connector loose, broken, defective
ï‚· Heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-55
Error Name
Perfect Binder: Ambient temperature error
Pattern
B
Error Condition
Ambient temperature is not within the operational range: It was between 0°C and -20°C.
Major Cause
ï‚· Internal temperature thermistor connector loose, broken, defective
ï‚· Thermistor defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
 Check the room temperature (0°C or higher).