1.SC Codes
492
Error Condition
The leading edge detect sensor A/D input value was lower than 3.2 to 3.54V, and the A/D input value
did not go higher than 3.2 to 3.54V, even after cover registration sensor A/D output value output was
higher than 3.7V.
Major Cause
ï‚· LE detect sensor connector loose, broken, defective
ï‚· Sensor defective
ï‚· Slave control board disconnected, defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the LE detect sensor.
ï‚· Replace the slave control board.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-66
Error Name
Perfect Binder: Entrance path sensor adjustment high value error
Pattern
B
Error Condition
When the entrance path sensor was adjusted, the sensor A/D input was less than 2.58 V, even after the
sensor D/A output was more than 3.3V.
Major Cause
ï‚· Entrance path sensor connector loose, broken, defective
ï‚· Sensor defective
ï‚· Cutter control board disconnected, defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the entrance path sensor.
ï‚· Replace the cutter control board.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.