EasyManua.ls Logo

Ricoh Pro 8320 - Sc754-72

Ricoh Pro 8320
963 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.SC Codes
549
ï‚· Connector or harness loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the MG motor (F).
ï‚· Replace the MG encoder sensor (F).
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-72
Error Name
Perfect Binder: Signature Exit Path HP Sensor Late Error
Pattern
B
Error Condition
During signature output roller separation, the signature exit path sensor did not go ON, even after the
signature exit path motor was ON for 750 ms.
Major Cause
ï‚· Signature path exit motor defective
ï‚· Signature path exit HP sensor defective
ï‚· Connector loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the signature path exit motor.
ï‚· Replace the signature path exit HP sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.

Table of Contents

Other manuals for Ricoh Pro 8320

Related product manuals