55: [Ppr Trns CV Start Timing: B&W: Side 2]
Adjust the timing to start constant voltage control for the bias on Side 2 during paper transfer when
printing in black-and-white mode.
Use this to adjust transferability at the leading edge of the paper.
Press [+] or [−] to adjust the start timing.
Setting Items Max. Value Min. Value Step Unit
[Ppr Trns CV Start Timing: B&W: Side 2] 100 0 1 ms
56: [Ppr Trns CV Start Timing: FC: Side 1]
Adjust the timing to start constant voltage control for the bias on Side 1 during paper transfer when
printing in full color.
Use this to adjust transferability at the leading edge of the paper.
Press [+] or [−] to adjust the start timing.
Setting Items Max. Value Min. Value Step Unit
[Ppr Trns CV Start Timing: FC: Side 1] 100 0 1 ms
57: [Ppr Trns CV Start Timing: FC: Side 2]
Adjust the timing to start constant voltage control for the bias on Side 2 during paper transfer when
printing in full color.
Use this to adjust transferability at the leading edge of the paper.
Press [+] or [−] to adjust the start timing.
Setting Items Max. Value Min. Value Step Unit
[Ppr Trns CV Start Timing: FC: Side 2] 100 0 1 ms
58: [Ppr Trns CV Cntrl Duratn: B&W: Side 1]
Adjust the duration of constant voltage control for the bias on Side 1 during paper transfer when printing
in black-and-white mode.
Use this to adjust transferability at the leading edge of the paper.
Press [+] or [−] to adjust the duration.
4. Details of Menu Items in Advanced Settings
100