010
Factory Setting:L:GO *ENG [0 to 1023 / 0 / 1digit/step]
Display/Saves White level peak scanning value (L side/GREEN/ODD) for factory light
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
011
Factory Setting:L:BE *ENG [0 to 1023 / 0 / 1digit/step]
Display/Saves White level peak scanning value (L side/BLUE/EVEN) for factory light
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
012
Factory Setting:L:BO *ENG [0 to 1023 / 0 / 1digit/step]
Display/Saves White level peak scanning value (L side/BLUE/ODD) for factory light
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4902 [Disp ACC Data]
001
R_DATA1 *ENG [0 to 255 / 0 / 1/step]
Displays (0 to 255) scan value (R component) of scanner for AAC pattern (white
background area)
002
G_DATA1 *ENG [0 to 255 / 0 / 1/step]
Displays (0 to 255) scan value (G component) of scanner for AAC pattern (white
background area)
003
B_DATA1 *ENG [0 to 255 / 0 / 1/step]
Displays (0 to 255) scan value (B component) of scanner for AAC pattern (white
background area)
004
R_DATA2 *ENG [0 to 255 / 0 / 1/step]
Displays (0 to 255) scan value (R component) of scanner for AAC pattern (Cyan max.
density area)
SP4-XXX (Scanner)
183