1.SC Codes
100
Error Name/Error Condition/Major Cause/Solution
Development Unit Cooling Fan 1 Error
Development Unit Cooling Fan 2 Error
Development Unit Cooling Fan 3 Error
During fan lock detection
Fan stopped due to overload or foreign object
Connector disconnected.
Check the connector. Replace the defective fan.
Error Name/Error Condition/Major Cause/Solution
Thermistor disconnection: Heating Roller Thermopile
Heating Roller Thermopile detected -40 degree or lower 3 seconds consecutively
after the heater was turned on.
Thermistor disconnection
Connecter contact failure
Replace the Heating Roller Thermopile.
Reconnect the connector.
Replace the fuser unit.
Error Name/Error Condition/Major Cause/Solution
Reload Failure: Heating Roller Thermopile
Heating Roller Thermopile detected a temperature below 80 degrees 65 seconds
consecutively after the heater was turned on.
Thermistor deformed or floating
Input voltage out of specification
Replace the Heating Roller Thermopile
Use within the input voltage specification.
Replace the fuser unit.
Replace the heater.
Error Name/Error Condition/Major Cause/Solution
Reload Failure: Heating Roller Thermopile
200 seconds after start of heater control, Heating Roller Thermopile detected that
temperature has not been reached for reload permission.