1.SC Codes
101
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
After the operation of overheat prevention mechanism
Heater broken
Replace the Heating Roller Thermopile
Use within the input voltage specification.
Replace the heater.
Replace the fuser unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC543-
00
A
Overheat detection (software): Heating Roller Thermopile
Heating Roller Thermopile detected a temperature of 237 degrees or higher
continuously for 30 seconds or longer.
Measurement period: 100 milliseconds
Triac shorted.
IOB board defective.
fuser unit controller software runaway
Replace the IOB board.
Replace the fuser unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC545-
01
SC556-
01
A
Heater lit continuously : Heating Roller Fusing Lamps
The DUTY of heater was equal to the maximum DUTY (excluding 0%) for 115
seconds or more continuously after the heater was turned on during Ready
status/preheating/low-power and the fuser unit stopped.
Excluded time: 140 seconds after reload/paper feed
The time it takes to reach the reload temperature/waiting target temperature at
rated input -25% + heater tolerance is excluded (300 seconds).
Thermistor deformed or floating
Heater disconnection
After the operation of overheat prevention mechanism
Replace the Heating Roller Thermopile
Replace the Heating Roller Fusing Lamps.
Replace the Fuser Unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC546-
00
A
Thermistor disconnection: Heating Roller Thermistor
Heating Roller Thermistor detected 0 degree or lower 50 seconds consecutively
after the heater was turned on