1.SC Codes
333
Error Name/Error Condition/Major Cause/Solution
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Stack weight move HP sensor late error
When the tray moved to the home position, the stack weight move HP sensor did
not go ON after enough time for 70mm of movement had elapsed.
Stack weight HP sensor defective
Stack weight motor defective
Harness connector loose, broken, defective
Master control board defective
Reconnect the connector.
Replace the stack weight motor.
Replace the stack weight HP sensor.
Replace the master control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Stack weight HP sensor lag error
During movement away from the HP sensor, the HP sensor did not go OFF after
enough time for 10mm of movement had elapsed.
Stack weight HP sensor defective
Stack weight motor defective
Harness connector loose, broken, defective
Master control board defective
Reconnect the connector.
Replace the stack weight motor.
Replace the stack weight HP sensor.
Replace the master control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power