1.SC Codes
334
Error Name/Error Condition/Major Cause/Solution
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Sub grip HP sensor late error
During the sub grip lift operation, the sub grip upper HP sensor did not go ON,
even though the sub grip lift motor had operated for 4110 ms.
Sub grip lift motor defective
Sub grip upper HP sensor defective
Harness connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the sub grip lift motor.
Replace the Sub grip upper HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Sub grip HP sensor lag error
During sub grip lowering, the sub grip lower HP sensor did not go OFF, even
though the sub grip lift motor had operated for 240 ms.
Sub grip lift motor defective
Sub grip upper HP sensor defective
Harness connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the sub grip lift motor.
Replace the Sub grip upper HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.