1.SC Codes
42
Error Name/Error Condition/Major Cause/Solution
ID Sensor Pattern Density High Error (S)
ID Pattern adhesion (SP3-300-001 to 005) > Upper limit threshold (SP3-301-081
to 085)
Error Name/Error Condition/Major Cause/Solution
ID Sensor Pattern Density Low Error (K)
ID Sensor Pattern Density Low Error (C)
ID Sensor Pattern Density Low Error (M)
ID Sensor Pattern Density Low Error (Y)
ID Sensor Pattern Density Low Error (S)
ID Pattern adhesion (SP3-300-001 to 005) < Lower limit threshold (SP3-301-091
to 095) for three times in a row.
Abnormal development bias (Continuity fault)
Check development bias continuity.
Check the image transfer unit.
Error Name/Error Condition/Major Cause/Solution
Potential sensor output high error (K)
Potential sensor output high error (C)
Potential sensor output high error (M)
Potential sensor output high error (Y)
Potential sensor output high error (S)
Vd(700) greater than 800[-V]