1.SC Codes
106
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Replace the Pressure Roller Fusing Lamp
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC553-
00
A
Overheat detection (software): Pressure Roller NC Sensor
Pressure Roller NC Sensor detected 220 degrees or higher 1 second
consecutively.
Measurement period: 100 milliseconds
Triac shorted.
IOB board defective.
Fuser Unit controller software runaway
Replace the IOB board.
Replace the Fuser Unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC554-00
A
Overheat detection (hardware): Pressure Roller NC Sensor
Pressure Roller NC Sensor detected 260 degrees or higher.
Triac shorted.
IOB board defective.
Fuser Unit controller software runaway
-
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC555-
00
A
Heater lit continuously: Pressure Roller Fusing Lamp
The DUTY of Pressure Roller Fusing Lamp was equal to the maximum DUTY
(excluding 0%) for 55 seconds continuously after the heater was turned on during
Ready status/preheating/low-power and the fuser unit stopped.
Excluded time: 200 seconds
Thermistor deformed or floating
Heater disconnection
Overheating prevention device worked.
Replace the Pressure Roller NC Sensor
Replace the Pressure Roller Fusing Lamp
Replace the Fuser Unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC557-00
C
Zero Cross Error (high frequency)
The AC power supply frequency is high or unstable.