1.SC Codes
106
Error Name/Error Condition/Major Cause/Solution
Replace the Pressure Roller Fusing Lamp
Error Name/Error Condition/Major Cause/Solution
Overheat detection (software): Pressure Roller NC Sensor
Pressure Roller NC Sensor detected 220 degrees or higher 1 second
consecutively.
Measurement period: 100 milliseconds
Triac shorted.
IOB board defective.
Fuser Unit controller software runaway
Replace the Fuser Unit.
Error Name/Error Condition/Major Cause/Solution
Overheat detection (hardware): Pressure Roller NC Sensor
Pressure Roller NC Sensor detected 260 degrees or higher.
IOB board defective.
Fuser Unit controller software runaway
Error Name/Error Condition/Major Cause/Solution
Heater lit continuously: Pressure Roller Fusing Lamp
The DUTY of Pressure Roller Fusing Lamp was equal to the maximum DUTY
(excluding 0%) for 55 seconds continuously after the heater was turned on during
Ready status/preheating/low-power and the fuser unit stopped.
Excluded time: 200 seconds
Thermistor deformed or floating
Heater disconnection
Overheating prevention device worked.
Replace the Pressure Roller NC Sensor
Replace the Pressure Roller Fusing Lamp
Replace the Fuser Unit.
Error Name/Error Condition/Major Cause/Solution
Zero Cross Error (high frequency)
The AC power supply frequency is high or unstable.