1.SC Codes
108
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC560-
00
C
Web contact/separation error
Failure in control of "from separation to contact" and "from contact to separation"
was detected three times in a row.
Fuser belt smoothing roller contact motor defective.
Fuser belt smoothing roller pressure sensor defective
Filler deformed or damaged
Contact/separation mechanism damaged
Replace the Fuser belt smoothing roller contact motor.
Replace the Fuser belt smoothing roller pressure sensor.
Replace the feeler.
Replace the fuser unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC561-
00
A
Thermistor disconnection: Heating Roller NC Sensor
Heating Roller NC Sensor detected 0 degree or lower 35 seconds consecutively
after the heater was turned on
Thermistor disconnection
Connecter contact failure
Replace the Heating Roller NC Sensor.
Reconnect the connector
Replace the unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC563-
00
A
Overheat detection (software): Heating Roller NC Sensor
Heating Roller NC Sensor detected 255 degrees or higher 10 seconds
consecutively.
Measurement period: 100 milliseconds
Triac shorted.
IOB board defective.
Fuser Unit controller software runaway
Replace the IOB board.
Replace the Fuser Unit.
Replace the AC drive board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC564-00
A
Overheat detection (hardware): Heating Roller NC Sensor
Heating Roller NC Sensor detected 270 degrees or higher.