1.SC Codes
137
Error Name/Error Condition/Major Cause/Solution
IOB defective
CIS defective
1. Cycle the machine off/on.
2. Reconnect the harness between CIS and CRB-R.
3. Reconnect the harness between CRB-R and IOB.
4. Replace the harness between CIS and CRB-R.
5. Replace the harness between CRB-R and IOB.
6. Replace the CRB-R.
7. Replace the CIS.
8. Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
Fusing: ID Chip Communication Error
I2C BUS OPEN: (Invalid Device ID)
I2C BUS OPEN: (Channel error (e.g. bus disconnection))
I2C BUS OPEN: (Device Error (No ID chip))
I2C BUS OPEN: (Communication aborted (error during communication))
I2C BUS OPEN: (Communication timeout)
I2C BUS OPEN: (Device stopped (logically stopped))
I2C BUS OPEN: (Requested buffer full)
I2C BUS OPEN: (No error code)
I2C BUS CLOSE: (Invalid Device ID)
I2C BUS CLOSE: (No error code)
I2C BUS Data read: (Invalid Device ID)
I2C BUS Data read: (Channel error (e.g. bus disconnection))