Setting Item Max. Value Min. Value Step Unit
26: Heat Roller Temp: Clear/Special/27:
Heat Roller Temp: White/28: Heat Roller
Temp: Metallic/29: Heat Roller Temp:
Option
200 100 1 Degree C
30: Corct Temp: Init Fd: Clear/
Special/31: Corct Temp: Init Fd:
White/32: Correct Temp: Initial Feed:
Metallic/33: Correct Temp: Initial Feed:
Option/34: Corct Temp: Pre-Fd: Clear/
Special/35: Corct Temp: Pre-Fd:
White/36: Correct Temp: Pre-Feed:
Metallic/37: Correct Temp: Pre-Feed:
Option
30 0
38: Init Sht Intvl: Low: Clear/Special/39:
Init Sht Intvl: Low: White/40: Initial Sheet
Interval: Low: Metallic/41: Initial Sheet
Interval: Low: Option/42: Init Sht Intvl:
Clear/Special/43: Init Sht Intvl:
White/44: Initial Sheet Interval:
Metallic/45: Initial Sheet Interval: Option
3 None
BW/FC/FCS: Fuser Setting HQ
Under the following conditions, adjust heat roller temperature, temperature correction, initial sheet
interval.
B & W/Full Color/Full Color including Special
High Quality is not applied in DFE Setting
Setting Item Max. Value Min. Value Step Unit
46: Heat Roller Temp 200 100 1 Degree C
47: Corct Temp: Initial Feed/48: Corct
Temp: Pre-Feed
30 0
49: Initial Sheet Interval: Low/50: Initial
Sheet Interval
3 None
4. Adjustment Setting Items for a Custom Paper
176