Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
[Black] 0 5 -5 1 None
[Cyan]
[Magenta]
[Yellow]
0204 [Fusing Temperature on Standby]
Adjust the fusing conditions in the standby status.
Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
[Heat Rlr: On Standby] 163 200 100 1 deg
[Press Rlr: On Panel Off] 50 30
[Heat Rlr: On Low Power] 80 0
[Machine: Image Quality]
31