0623 [Z-fold Skew Correction]
Select way to correct skew during Z-folding. [On] corrects by striking. [On: Reverse] corrects by both
striking and reverse rotation of Regist. Roller.
Setting Item Values Default Value
[Setting] [Off]
[On]
[On: Reverse]
[On: Reverse]
0624 [Amount of Z-fold Skew Correction]
Adjust striking amount of paper during Z-folding skew correction. It is used when side effects occur. The
initial setting of paper striking is 9mm and becomes 0mm by setting [-9].
Setting Item
Default
Value
Max.
Value
Min.
Value
Step Unit
[Setting] 0.0 0.0 -9.0 0.5 mm
0625 [Amount of Z-fold Skew Correction: Reverse]
Adjust the reverse rotation amount of Registration Roller during Z-folding Skew Correction. It is used
against side effects. The initial setting is 3mm and becomes 0mm by setting [-3].
[Finishing: Finisher]
67