1246: Fusing Nip Width Adjustment
Adjust the contact width (nip width) between fusing belt and pressure roller.
Setting Item Max. Value Min. Value Step Unit
01: Other than Envelope 3 1 1 None
02: Envelope 2,000 0 msec
1247: Fusing Temperature Range
BW/FC
Specify the fusing temperature to allow feeding of paper in the following conditions:
When performing any type of printing including B&W printing and Full Color printing.
When the High Quality setting is not applied in the DFE setting.
Pressing makes the printing start faster, but may degrade the fusing quality.
Setting Item
Max.
Value
Min.
Value
Step Unit
01: Heat 16 1 1 None
02: Pressure
1249: Fusing Belt Smoothing
Interval
Adjust the interval to execute the auto smoothing fusing belt. Select a higher frequency for greater
smoothness, this may reduce the life of the smoothing roller.
4. Adjustment Setting Items for a Custom Paper
168