1. Press the [Maintenance] key.
2. Press [ ].
3. Press [Special Maintenance].
Check the nozzle immersion time to be displayed on the control panel. If you do not change the
nozzle immersion time, proceed to Step 6.
4. Press [Nozzle Immersion Time].
5. Enter the immersion time to immerse print heads into caps using the number keys, and
then press [Set].
6. Press [Nozzle Maintenance].
7. Press [Execute].
The carriage moves to the left side edge position.
5. Troubleshooting
186