145 English
SPECIFICATIONS
Supplied battery pack charger
i When using the supplied battery pack charger abroad, the power cord may
need to be replaced in accordance with local requirements.
Supplied Li-ion battery pack
Part No. BJ–8
Power source AC 100 to 240 V, 50 to 60 Hz, 2.6 W
Rated output DC 4.2 V, 330 mA
Compatible batteries Supplied or separately sold Lithium-ion
battery pack (DB-80)
Ambient
environment
Temperature
0 to 40°C (32 to 104°F) (recharge),
–20 to 60°C (–4 to 140°F) (storage)
Humidity 20 to 80% (no condensation)
Dimensions
62 (W) × 23.8 (H) × 90 (D) mm
2.44" (W) × 0.94" (H) × 3.54" (D)
Weight (without power cord) Approx. 63 g (2.22 oz.)
Power cord rated value
AC 125 V, 7 A/AC250 V, 2.5 A (A cable
specific to the country of destination is
supplied)
Part No. DB-80
Voltage 3.7 V
Rated output 680 mAh
Ambient
environment
Temperature 0 to 40°C (32 to 104°F) (during use,
recharged)
–10 to 30°C (14 to 86°F) (storage)
Humidity 10 to 90% (no condensation)
Dimensions 26.9 (W) × 7.5 (H) × 38 (D) mm
1.06 (W) × 0.30 (H) × 1.50 (D) in.
Weight Approx. 15 g (0.53 oz.)