Procedure for long-term storage
15 / 22
carriage so as not to spill it.
When the head protection cover is tilted, the angle at which the cleaning liquid inside
the cap spills out is "left to right: approx. 30 degrees" and "front to back: approx. 10
degrees" when the head protection cover is filled with cleaning liquid to the target
state.
Therefore, when installing the head protection cover, move it carefully so that it tilts
to the left or right to some extent, but not to the front or rear.
4.Push the head protection cover up until it clicks into place.
Wipe up any cleaning solution spilled when the head protection cover is pushed up.