0: OFF (Remote service off)
2: Network (@Remote remote service on)
5816 002
CE Call
Performs the CE Call at the start or end of the service.
[0 or 1 / 0 / 1 /step]
0: Start of the service
1: End of the service
NOTE: This SP is activated only when SP 5816-001 is set to "2".
5816 003
Function Flag
Enables or disables the remote service function.
[0 to 1 / 0 / 1 /step]
0: Disabled
1: Enabled
5816 007
SSL Disable
Uses or does not use the RCG certification by SSL when calling the RCG.
[0 to 1 / 0 / 1 /step]
0: Uses the RCG certification
1: Does no use the RCG certification
5816 008
RCG Connect Timeout
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 10 / 1 second /step]
5816 009
RCG Write Timeout
Specifies the write timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
5816 010
RCG Read Timeout
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
5816 011
Port 80 Enable -
Enables/disables access via port 80 to the SOAP method.