This SP sets the address of the proxy server used for communication between embedded
RCG-N and the gateway. Use this SP to set up or display the customer proxy server
address. The address is necessary to set up embedded RCG-N.
Note: The address display is limited to 128 characters. Characters beyond the 128
character are ignored.
This address is customer information and is not printed in the SMC report.
5816 064
Proxy Port Number
This SP sets the port number of the proxy server used for communication between
embedded RCG-N and the gateway. This setting is necessary to set up embedded RCG-
N.
Note: This port number is customer information and is not printed in the SMC report.
5816 065
Proxy/User Name
This SP sets the HTTP proxy certification user name.
Note:
The length of the name is limited to 31 characters. Any character beyond the 31st
character is ignored.
This name is customer information and is not printed in the SMC report.
5816 066
Proxy Password
This SP sets the HTTP proxy certification password.
The length of the name is limited to 31 characters. Any character beyond the 31st
character is ignored.
This name is customer information and is not printed in the SMC report.
5816 067
Cert: Up State
Displays the status of the certification update.
0 The certification used by embedded RCG is set correctly.
1
The certification request (setAuthKey) for update has been received from the GW
URL and certification is presently being updated.
2
The certification update is completed and the GW URL is being notified of the
successful update.
3
The certification update failed, and the GW URL is being notified of the failed
update.
Printer Engine Service Mode