2-53
Confidential
Error code BB00
A white level not within the standard was scanned when function code 55 was executed.
Error code BD00
A black level not within the standard was scanned when function code 55 was executed.
Step Cause Remedy
1 Dirt on the document hold Clean the document hold.
2 Dirt on the white tape Clean the white tape.
3 CIS unit failure Replace the CIS unit.
4 Document hold failure Replace the ADF unit.
5 White tape failure Replace the document scanner unit.
6 Main PCB failure Replace the main PCB ASSY.
Step Cause Remedy
1 Dirt on the document hold Clean the document hold.
2 Dirt on the white tape Clean the white tape.
3 CIS unit failure Replace the CIS unit.
4 Document hold failure Replace the ADF unit.
5 White tape failure Replace the document scanner unit.
6 Main PCB failure Replace the main PCB ASSY.