2809
2
1.1 BURNER EQUIPMENT
Flange with insulating gasket . . . . . . . . . No. 1 4 pole socket . . . . . . . . . . . . . . . . . . . . . . . . No. 1
Screw and nut for flange . . . . . . . . . . . . . No. 4 Cable grommet . . . . . . . . . . . . . . . . . . . . . . No. 1
Flexible pipe with nipple . . . . . . . . . . . . . No. 1 Screw with two nuts for flange . . . . . . . . . . . No. 1
Screw of by-pass pump . . . . . . . . . . . . . . No. 1 4 pin plug . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
2. TECHNICAL DATA
2.1 TECHNICAL DATA
2.2 OVERALL DIMENSIONS
TYPE 510 T1K 510 T3K
Output
Thermal power
1.4 – 2.2 kg/h
16.8 – 26.3 kW
2 – 3 kg/h
24 – 35.9 kW
Fuel
Kerosene, viscosity 1.6 – 6 mm
2
/s at 20 °C (H
i
= 11.97 kWh/kg)
Light oil, viscosity 4 – 6 mm
2
/s at 20 °C (H
i
= 11.86 kWh/kg)
Electrical supply Single phase,
~ 50Hz 230V ± 10%
Motor Run current 0.7A 2850 rpm 298 rad/s
Capacitor 4 F
Ignition transformer Secondary 8 kV 16 mA
Pump
Kerosene, maximum pressure 10 bar (145 psi)
Light oil, maximum pressure 15 bar (218 psi)
Absorbed electrical power 0.115 kW
Flange Burner
252
86 203
130
=
19
4
5
°
215
11
164
D6253
=
180
75 72
150
4
5
°
ø 89