3.5 ELECTRICAL WIRING
DO NOT EXCHANGE
NEUTRAL WITH PHASE
WARNING
CONTROL BOX
To remove the control-box from the burner, loosen screw (A, fig. 11) and pull
to the arrow direction, after removing all components, the 7 pin plug and
earth wire.
In case of disassembly of the control box, retighten the screw (A) with a
torque wrench setting of 1 – 1.2 Nm.
7 pin plug
7 pole socket
h
L1
B4S3
T2
T1
N
Black
White
Blue
Capacitor
Burner-earth
Main switch
T6A
Neutral
CONTROL BOX
552SE
~
50/60Hz 220/230V
N
1
2
3
Photoresistance
T
Blue
Ignition
electrodes
Brown
L
T
h
T
2
nd
stage oil valve
T8
T7
T6B5
4 pin plug
4 pole socket
Blue
Black
White
Blue
Brown
2 1
3 2 1
M
~
ELECTRONIC
DELAYING DEVICE
2
nd
stage
Motor
thermostat
M
1
2
1
2
3
M
CARRIED-OUT IN THE FACTORY
1
st
stage oil valve
D4958
Limit thermostat
Remote lock-out signal
(230V - 0.5A max.)
Safety
1
st
stage
hour counter
(230V - 0.1A max.)
2
nd
stage hour counter
(230V - 0.1A max.)
Brown
Blue
S7120
Fig. 11
A
NOTES:
Wires of min. 1 mm
2
section. (Unless requested otherwise
by local standards and legislation).
The electrical wiring carried out by the installer must be in
compliance with the rules in force in the Country.
Connect 2nd stage thermostat between clamps T6 - T8
by removing the bridge.
TESTING: Check the shut-down of the burner by opening
the thermostats and the lock-out by darkening
the photoresistance.
thermostat
TO BE DONE BY THE INSTALLER