USER’S MANUAL
MODEL: VST-WC588IH
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This users manual contains important information about your Alarm’s operation. If you are installing the Alarm for use by others, you
must leave this manual—or a copy of it—with the end user.
WIRELESS CARBON MONOXIDE ALARM
MAIN FEATURES
¾ DC operated Wireless Interconnectable carbon monoxide alarm
¾ Electrochemical CO sensor
¾ Test / Hush Button
¾ High and stable sensitivity
¾ With quick fix mounting bracket for easy installation
¾ Fitting and battery tamper-resist feature
¾ LED operation indicator
¾ Extra loud alarm sound over 85 dB at 1m
¾ Low-battery and battery missing warning indicator
¾ Auto reset after CO is clear
SPECIFICATION
¾ Detection Type: Electrochemical CO sensor
¾ Power Source: 9V(6F22) Battery
¾ Working frequency: 868MHz
¾ Emission distance: >60mopen space
¾ Standby Current: 25uA max
¾ Alarm Current: 40mA max
¾ CO Alarm Level: 50ppm (Between 60-90 min)
100ppm (Between 10-40 min)
300ppm (<3min.)
¾ Alarm Sound Level 85 Decibels at 1 meter
¾ Operation Temperature: 4 to 40
¾ Ambient Humidity: 15% to 90% Relative Humidity
¾ Compact size: 110mm diameter
IMPORTANT SAFETY INFORMATION
1. WHAT IS CARBON MONOXIDE?
Carbon monoxide is a colorless, odorless and tasteless poison gas that can be fatal when inhaled. CO blinds to the hemoglobin in the
blood and inhibits its capacity to carry oxygen. CO kills hundreds of people each year and injures many more because it is difficult to
be detected with the human senses. In high concentrations, CO can kill in minutes.
2. SOURCES OF CARBON MONOXIDE

Questions and Answers

  • S
    smithvanessaAug 11, 2025
    Why does my rientalert VST-WC588IH Carbon Monoxide Alarm sound frequently?
    • J
      Jill RossAug 11, 2025
      If your rientalert Carbon Monoxide Alarm sounds frequently, even though investigations reveal no high CO levels, it could be due to several reasons. First, your unit might be set to the same ID as a nearby system; in this case, change the ID of your units, making sure to turn off power to all units before changing the switch positions. Wireless interference could also be the cause, so try moving the other units to a new location. Lastly, the alarm might be improperly located, so relocate it. If the frequent alarms continue, have your home rechecked for potential CO problems, as you may be experiencing an intermittent CO issue.
  • J
    Jeanette ColemanAug 17, 2025
    What to do if not all rientalert VST-WC588IH devices produce an alarm signal when one is tested?
    • C
      carrie62Aug 17, 2025
      If not all alarms/accessories produce a signal when one rientalert Carbon Monoxide Alarm device is tested, it may be because the devices are not all on the same ID. Locate the 5-position dipswitch on the back of each unit and ensure that all corresponding switches are set the same. If an ID needs to be changed: remove power, press and hold the button for a minimum of 10 seconds, change the ID, and reapply power. Also, check that the battery is properly attached to the connector, as devices may not have power. Finally, there may be too much interference between units, so move the other units to a new location and try again, locating the wireless units as closely to each other as possible.
  • E
    Erik CoxAug 23, 2025
    Why does my rientalert Carbon Monoxide Alarm chirp every minute?
    • A
      Anna MillerAug 23, 2025
      If your rientalert Carbon Monoxide Alarm horn sounds one short chirp every minute, it indicates a low battery. Replace the battery, referring to the 'REGULAR MAINTENANCE' section for detailed instructions.
  • N
    Nicole LoweAug 29, 2025
    What does it mean when my rientalert VST-WC588IH chirps 3 times?
    • E
      Elizabeth HowellAug 30, 2025
      If the horn of your rientalert Carbon Monoxide Alarm sounds 3 quick chirps every minute, this indicates a malfunction signal, meaning the CO Alarm needs to be replaced. If your CO Alarm is under warranty, it should be returned to the manufacturer for replacement.
  • J
    jaclyn14Sep 4, 2025
    What to do if my rientalert VST-WC588IH chirps twice and then a long chirp?
    • J
      James GardnerSep 4, 2025
      If your rientalert Carbon Monoxide Alarm horn sounds 2 quick chirps followed by 1 long chirp, this indicates a malfunction signal, and the CO Alarm needs to be replaced. CO Alarms under warranty should be returned to the manufacturer for replacement.

rientalert VST-WC588IH Specifications

General IconGeneral
Brandrientalert
ModelVST-WC588IH
CategoryCarbon Monoxide Alarm
LanguageEnglish