Programmable Relay User Manual for ELC, EXM and PR Series 353 2020 v6.0 © Rievtech Co.,
Ltd. www.rievtech.com
PR-24AC-R PR-24DC-DA-R PR-24DC-DAI-RTA
(Unit: mm)
PR-E-16AC-R PR-E-16DC-DA-R PR-E-16DC-DA-TN PR-E-AI-I PR-E-PT100 PR-E-AQ-VI PR-E-RS485 (Unit: mm)PR-EExpantion Modules
RS232 Cable USB Cable PRO-RS485 Cable PR-Copier PR-Battery PR-Memory
(Unit: mm)OptionalAccessories
AC 110-240V AC 110-240V
L
Q1
N I1 I2 8x
4x
PR-E-16AC-R
POWER 5 0/60Hz INPUTS
OUTPUTS
RELAY 3A 2 5 0V RELAY 10A 2 50V
I8
Q2 Q4 Q5
4x
Q6 Q8
AC 110-240V AC 110-240V
PR-E-16AC-R
EXTENSION
PORT
EXTENSION
PORT
Universal Port
Extention
Port
Keypad
RS485 Port
LCD
PR-24Series
FrontView SideView Mounting
PR-24DC-DAI-RTA
L+
Q1 Q2 Q6
M I1 I2 I5 I64x
6x
PR-24DC-DAI-RTA
POWER INPUTS RS48 5 PORT
OUTPUTS
TRANSISTOR
PNP 0.5A
12-24V DC
RELAY
10A 2 50V
I4 I7 I8 8x IE
UNIVERSAL
PORT
EXTENSION
PORT
DC 12-24V DC 12-24V or 0-10V DC 0/4-20mA
RS485 Bus
B A
DC 12-24V
Q7 Q8
+ ANALOG
0-10V OR
0-20 mA
Q9
+
A
PR-24DC-DA-R
L+
Q1 Q2 Q6
M I1 I2 6x
10x
PR-24DC-DA-R
POWER INPUTS RS48 5 PORT
OUTPUTS
RELAY
10A 2 50V
I6 I7 I8 8x IE
UNIVERSAL
PORT
EXTENSION
PORT
DC 12-24V DC 12-24V or 0-10V
RS485 Bus
B A
DC 12-24V
AC 110-240V AC 110-240V
L
Q1 Q2 Q4
N I1 I2 14x
10x
PR-24AC-R
POWER 50 /60Hz INPUTS
OUTPUTS
RELAY 10A
250V
IA
AC 110-240V AC 110-240V
PR-24AC-R
RS48 5 PORT
RS485 Bus
B A
UNIVERSAL
PORT
EXTENSION
PORT
FrontView SideView Mounting
Extention
Port
Run/Stop Indicator
L+ M I1 I2 4x
POWER INPUTS
I6 I7 I4x
DC 12-24V DC 12-24V or 0-10V DC 12-24V
PR-E-16DC-DA-R
PR-E-16DC-DA-R
EXTENSION
PORT
EXTENSION
PORT
Q1
4x
OUTPUTS
RELAY 3A 2 5 0V RELAY 10A 2 50V
Q2 Q4 Q5
4x
Q6 Q8
L+ M I1 I2 4x
POWER INPUTS
I6 I7 I
4x
DC 12-24V DC 12-24V or 0-10V
DC 12-24V
PR-E-16DC-DA-TN
PR-E-16DC-DA-TN
EXTENSION
PORT
EXTENSION
PORT
OUTPUTS
Q1
8x
Q2 Q8
TRANSISTOR
PNP 0.5A
12-24V DC
+ + +
L+ M I1 I2 4x
POWER INPUTS
I4
DC 12-24V DC 0/4-20 mA
PR-E-AI-I
PR-E-AI-I
EXTENSION
PORT
EXTENSION
PORT
L+ M I1 I2 3x
POWER INPUTS
I3
DC 12-24V RTD PT100
PR-E-PT100
PR-E-PT10 0
EXTENSION
PORT
EXTENSION
PORT
L+ M
POWER
DC 12-24V
PR-E-AQ-VI
PR-E-AQ-VI
EXTENSION
PORT
EXTENSION
PORT
ANALOG
0-10V OR
0-20 mA
Q1 Q2
A A
RS48 5 PORT
RS485 Bus
L+ M
POWER
DC 12-24V
PR-E-RS485
PR-E-AQ-VI
EXTENSION
PORT
EXTENSION
PORT
A B
Cables
Length: 2m
Length: 2m
PR-series
peripheral connector
PR-6, PR-12, PR-14, PR-18
PR-24
PR-6, PR-12, PR-14, PR-18
PR-24
PR-6, PR-12, PR-14, PR-18
PR-24
PR-series
peripheral connector
PR-series
peripheral connector
D-Sub connector
(9-pin female)
USB typeA
plug connector (male)
Terminal block
connector
RS232 Cable
Model ompatibility
USB Cable
Length: 2m
PRO-RS485
Cable
Accessories
PR-6, PR-12, PR-14, PR-18
PR-24
PR-6, PR-12, PR-14, PR-18
PR-24
PR-6, PR-12, PR-14, PR-18
PR-24
PR-COPIER can be used to save user
program and download program into
CPUs.
Battery for RTC (backup 3 years)
For Data Logging on a microSD Card
PR-Copier
Model DimensionsDescription ompatibility
PR-Battery
PR-Memory
CPU Model
Total I/O Power supply
AC: 110-240VAC
DC: 12-24V DC
Input type
N/A: Only Digital
DA: Digital andAnalog (0-10V)
DAI: Digital,Analog (0-10V) andAnalog (0/4-20 mA)
Output type
R: Relay
TN: Transistor PNP
RT: Relay andTransistor PNP
RTA: Relay,Transistor andAnalog
PR- -
x x x x x
-
x x xx x
Extention Module Model
Total I/O
Power supply
AC: 110-240VAC
DC: 12-24V DC
Input type
N/A: Only Digital
DA: Digital andAnalog (0-10V)
Output type
R: Relay
TN:Transistor PNP
PR-E- -
x x x x
-
x xx x
Combine I/O
Analog signal type
I: Current signal
VI: Current and/or voltage signal
x
Extention Module Model
Module type
AI:Analog inputs
PT100: RTD inputs PT100
AQ:Analog outputs
RS485: COM Module RS485
Analog I/O and Communication
PR-E- -