Infinity REU-V3232W /HD250E REU-V3232WC - 41 - Issue 1 - 8/09/03 ©Rinnai
19. Gas Conversion Procedure
1) Close the main gas valve.
Turn power OFF (disconnect the power cord).
2) Remove front cover. (4 screws)
3) Remove manifold (complete assembly). (7 screws)
4) Replace the manifold (complete assembly) and the
packing. (7 screws)
Note: Do not loose or damage the O-ring when
reassembling.
Ensure connections for the solenoid and sparker lead
are made properly.