EasyManuals Logo

Rinnai REU-VRM2632WC Service Manual

Rinnai REU-VRM2632WC
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
Infinity REU-VR3237WG /HD250e REU-VRM3237WC - 29 - Issue 1 - 19/05/09 ©Rinnai
To return to normal operation.
Press the ON/OFF button again while holding the Water Temperature “UP” (Hotter) button.
This feature will automatically shut down after 3 minutes.
Error History
To Display Error Memory (History)
(This feature will show the last 10 faults in sequence)
1. Turn off at the ON/OFF button. (This can be done during
operation)
2. Press the ON/OFF button while holding the Water Temperature
"UP" (Hotter) button.
The Sequence will be shown in the Water Temperature display.
Error Code will be shown in the Clock display. (See service
Manual for error codes).
Where there are less than a total of 9 errors, "FFF" or " - - " will
be displayed in the Clock display.